  • Item: 4-Zone Fire Alarm Control Panel
  • Model No.: AW-CFP2166-4
  • Mains Supply Voltage: 110VAC or 220VAC
  • Internal Power Supply: 27.2VDC
  • Total Output Current: 3A @ 220VAC
  • Backup Batteries: 12V 2.3AH × 2
  • Number of Detector Circuits: 4 (expandable up to 32)
  • End of Line Device: 6.8kΩ, 5% tolerance, 0.5–1W (color code: blue, grey, red, gold)
  • Call Point Resistor Value: 470Ω to 680Ω, 0.5 or 1 watt
  • Number of Sounder Circuits: 2
  • Sounder Outputs: 750mA, resettable fuse
  • Outputs Fused At: 600mA
  • Battery Fuse: 1.85A, resettable fuse
  • Relay Output Type: Normally Closed (NC) and Normally Open (NO)
  • Relay Maximum Current: 100mA
  • Maximum Bells per Output (50mA each): Up to 30
  • Conductor Size Range: 0.75mm² to 2.5mm²
  • Dimensions: 640mm × 390mm × 150mm
  • Weight (With Batteries): 13kg
In Stock (100 available)
1

Free delivery within Nairobi on orders of KES 5,000 or more. Otherwise delivery across Kenya is KES 300. The delivery fee is paid on delivery, not at checkout. Delivery information

100% Genuine Product
Easy Returns
Secure Paystack Checkout

Product Description

Asenware AW-CFP2166-4 4-Zone Fire Alarm Control Panel

The Asenware AW-CFP2166-4 is a conventional 4-zone fire alarm control panel built to comply with EN54 Part 2 and Part 4 standards. Designed for safety-critical environments, it supports smoke detectors, manual call points, bells, and sprinkler systems. With modular expansion capability up to 32 zones, dual-level control, and robust power output, this panel is ideal for small to medium-sized facilities. Its user-friendly design, low maintenance requirements, and optional GSM module for SMS alerts make it an efficient and cost-effective solution for fire protection systems.

Product Features

Standards Compliance

Designed according to EN54 Part 2 and Part 4 standards for reliable fire detection and system integrity.

Modular Expansion

Expandable from 1 zone up to 32 zones using additional modules, allowing flexible configuration for a wide range of applications.

Secure Two-Level Control

Features a lockable two-level control mode to restrict unauthorized access and enhance system security.

DC Power Supply Output

Provides 24VDC output to power detectors, indicators, and other connected devices.

Fire and Fault Signal Outputs

Equipped with relay outputs for fire and fault conditions, enabling connection to remote indicators or building management systems.

Dual General Sounder Outputs

Two sounder circuits are available, allowing distribution of audible alerts across different building areas.

Independent Zone Inputs

Each of the four zones supports a dedicated detector circuit, providing localized detection and response.

Zone Disable Function

Each zone can be independently disabled for maintenance or troubleshooting without affecting the rest of the system.

Manual Reset

A RESET button restores the panel to normal status after alarm or fault conditions are resolved.

Silence Function

The SILENCE button stops both the internal buzzer and external sounders, useful during false alarms or testing.

Manual Evacuation Button

The EVACUATE button initiates a full alarm condition manually for emergency evacuation scenarios.

Optional GSM Notification

An optional GSM module allows SMS alerts to be sent during fire events, providing off-site notifications.

Economical and Low Maintenance

Cost-effective design with simple operation and easy servicing make this panel ideal for budget-conscious installations.

Product Specifications

  • Item: 4-Zone Fire Alarm Control Panel
  • Model No.: AW-CFP2166-4
  • Mains Supply Voltage: 110VAC or 220VAC
  • Internal Power Supply: 27.2VDC
  • Total Output Current: 3A @ 220VAC
  • Backup Batteries: 12V 2.3AH × 2
  • Number of Detector Circuits: 4 (expandable up to 32)
  • End of Line Device: 6.8kΩ, 5% tolerance, 0.5–1W (color code: blue, grey, red, gold)
  • Call Point Resistor Value: 470Ω to 680Ω, 0.5 or 1 watt
  • Number of Sounder Circuits: 2
  • Sounder Outputs: 750mA, resettable fuse
  • Outputs Fused At: 600mA
  • Battery Fuse: 1.85A, resettable fuse
  • Relay Output Type: Normally Closed (NC) and Normally Open (NO)
  • Relay Maximum Current: 100mA
  • Maximum Bells per Output (50mA each): Up to 30
  • Conductor Size Range: 0.75mm² to 2.5mm²
  • Dimensions: 640mm × 390mm × 150mm
  • Weight (With Batteries): 13kg

You May Also Like

Sale Fire Hose Reel 19mm x 30m – 8 Bar Working Pressure

Fire Hose Reel 19mm x 30m – 8 Bar Working Pressure

No rating available
KES 25,000 33,000
Sale 4 Way Breaching Inlet Valves

4 Way Breaching Inlet Valves

No rating available
KES 26,000 30,000
Hi! What are you looking for today?